Welch Allyn

Baxter Welch Allyn 93700-NP MicroTymp 4 Portable Tympanometer

Write a Review
SKU:
WA93700-NP
MPN:
93700-NP
  • Baxter Welch Allyn 93700-NP MicroTymp 4 Portable Tympanometer with printer
  • Baxter Welch Allyn 93700-NP MicroTymp 4 Portable Tympanometer device
  • Baxter Welch Allyn 93700-NP MicroTymp 4 Portable Tympanometer kit
Normally: $4,999.00
YOUR PRICE $3,925.00
— You save $1,074.00

Description

FREE SHIPPING INCLUDED

What's In the Box:

  • Hand Set
  • TympView Software
  • USB Thumb Drive with DFUs
  • Ear Tip Starter Kit
  • 4-Volume Test Cavity
  • Serial Printer Cable
  • Probe Tip Cleaning Kit
  • Power Supply
  • USB Data Cable
  • Charging Cradle
  • Printer only included if added onto options

 

The Welch Allyn MicroTymp 4 Portable Tympanometer, a screening tympanometer, helps you verify otoscopy findings and empower your diagnosis of middle ear conditions with objective evidence. 

The Welch Allyn MicroTymp 4 Portable Tympanometer helps you verify middle ear conditions and improve diagnostic accuracy by providing objective analysis of tympanic membrane mobility and condition of the middle ear. This tympanometric instrument tests each ear in as little as three seconds and is ideal for pediatrics.

  • This diagnostic tympanometer supports tympanometry and ipsilateral acoustic reflex measurement testing
  • MicroTymp 4 automatically begins recording a tympanogram as soon as the ear canal seal is obtained
  • Test patients six months of age and up
  • Four-button navigation supports a quick, complete exam in L, R or both ears

Technical Specifications

Instrument Type

Meatus compensated tympanometer

Analysis Performed

Admittance peak level (in ml); Pressure of same; Gradient (in daPa); Ear Canal Volume (ECV) @ 200 daPa

Probe Tone – Levels & Accuracy

8226Hz +/- 2%; 85dB SPL +/-2dB over range 0.2ml to 5ml

Pressure – Levels & Accuracy

+200daPa to -400daPa +/-10daPa or +/-10% (whichever is larger) over range

Ear Volume – Measurement Range & Accuracy

0.2ml to 5ml +/- 0.1ml or +/-5% (whichever is larger) over entire range

Reflex Measurements

Measurement Mode

Ipsilateral

Reflex Tones

500Hz, 1kHz, 2kHz, 4kHz

Reflex Analysis

Reflex pass/fail at each level tested; maximum amplitude of each reflex (seen on printed report & computer report); pressure at which reflex was performed

Device Specifications

Test Capture

Up to 100 recordings on a full charge

Test Storage

Up to 32 test records

Battery

NiMH rechargeable battery pack. Not user replaceable

Mains Power (to cradle)

100-240Vac; 50/60Hz; 0.2A

Warm-up Period

None at room temperature

Display

128 x 64 pixels / 8 lines of 21 characters

Dimensions

230mm (L) x 115mm (W) x 70mm (H)

Weight (device and cradle)

650 grams / 1.43 pounds

Standards

Safety

IEC 60601-1 (plus UL, CSA & EN deviations)

EMC

IEC 60601-1-2

Performance

IEC 60645-5, Type 2 Tympanometer

1-year-warranty-made-in-the-usa.png

 

free-insurance-banner.png

 

Warranty

Manufacturer 1 year warranty on this item. Please click here for more information.

Shipping

Due to the size and weight, this item ships via ground. Shipping is included.

 

View AllClose

More Info

Manufacturer:
Welch Allyn
Manufacturer Part:
93700-NP
Ships Via:
Ground
+-