Compare Power Exam Tables

ADA power exam tables

Find the right ADA-compliant power exam table

Answer a few questions and we'll match you to the exact model and the accessories that make it accessible.

19″Required now: the table must lower to 19″ or below (HHS and DOJ rules)
17″2024 Access Board update. Not required yet; a 17″ table is covered if it's adopted
Step 1 of 6
Will this be your accessible (ADA) exam table?
See my recommendation

Recommended Product

Answer the first question to see it.

Popular power exam table comparisons

Midmark 224 vs 225Same 18″ chair. The 225's backrest is powered; the 224's moves by hand.

Same chair, different backrest. The 225 has a powered backrest; the 224's gas-spring backrest is moved by hand. Both lower to 18″, rise to 37″ and carry 500 lb. The 225 always includes the drawer heater, pelvic tilt and receptacles. The 224 also comes as a basic 224-001 without stirrups, pelvic tilt, drawer heater or receptacles. In September 2026 Midmark introduced the 17″ Ritter 228 (manual back) and 229 (powered back) as their successors.

UMF 3002 vs 3002-ACCESSThe -ACCESS version (FusionFREEDOM) lowers to 17″ instead of 19″ and takes ADA-compliant rails. It's rated 450 lb instead of 500 lb.

The -ACCESS suffix is UMF's FusionFREEDOM: the FusionONE platform and model numbering, rebuilt for the 2024 17″ standard. It lowers to 17″ instead of 19″, rises to 33″ instead of 32″, is rated 450 lb instead of 500 lb, and takes UMF's ADA-compliant TruComfort rails (587 or 588). Choose -ACCESS if this is your accessible table; the plain 3002 suits general exams and patients up to 500 lb. Storage differs too: on the FusionONE only the WheelBase models lose the side drawer, while on the FusionFREEDOM both the WheelBase and pelvic-tilt models do.

Midmark 224 vs 228The 228 replaced the 224. It lowers to 17″ instead of 18″.

The 228 is the 224's successor: same 37″ high height, 500 lb capacity and manual backrest, but it lowers to 17″ instead of 18″, meeting the 2024 standard. Midmark lists the 228 as compatible with patient lifts.

Midmark 225 vs 229The 229 replaced the 225. It lowers to 17″ instead of 18″.

The 229 is the 225's successor: same powered backrest, 37″ high height and 500 lb capacity, but it lowers to 17″ instead of 18″, meeting the 2024 standard. Midmark lists the 229 as compatible with patient lifts.

Midmark 228 vs 229Same 17″ chair. The 229's backrest is powered; the 228's is manual.

Identical 17″ chairs except for the backrest: the 229 is powered, the 228 is manual. The 228 also comes as a base model without stirrups, pelvic tilt, drawer heater or receptacles (228-001); both offer the Clean Assist roller base on the -003.

UMF FusionFREEDOM vs Midmark 228Both reach 17″. The 228 rises higher and carries more; the FusionFREEDOM offers a powered back and a 3-year warranty.

Both meet the 2024 17″ standard and both take compliant transfer rails. The Midmark 228 rises higher (37″ vs 33″), carries 500 lb versus 450 lb, and Midmark lists it as compatible with patient lifts. The UMF FusionFREEDOM offers a powered back (3502 and 3503-ACCESS), a reversible side drawer (not on pelvic-tilt or WheelBase models) and a 3-year warranty.

UMF FusionONE 3002 vs Midmark 224The 224 goes a little lower and much higher. The 3002 adds a side drawer and a longer warranty.

The Midmark lowers a little further (18″ vs 19″) and rises much higher (37″ vs 32″), which matters for clinicians who examine standing. Both carry 500 lb and both sit inside today's 17–19″ enforcement range. The UMF FusionONE adds a reversible side drawer (not on WheelBase models), offers a powered back on the 3502 and 3503 and carries a 3-year warranty (the 224 has 1 year). The 224-002 and -003 add receptacles, a heated drawer and pelvic tilt, and Midmark's Patient Support Rails are available as an accessory. Midmark introduced the 17″ Ritter 228 as the 224's successor in September 2026.

Midmark 229 vs 626The 626 lowers to 15.5″, carries 650 lb and offers a built-in scale.

Both meet the 2024 17″ standard with a powered back. The 626 goes lower (15.5″), carries 650 lb instead of 500 lb, includes the Clean Assist roller system on every model, and offers a built-in digital scale, heated upholstery and a 32″-wide top.

What makes a power exam table ADA compliant

The federal standard (36 CFR Part 1195) has six requirements. A table needs all of them.

17″

Low transfer height

Lowers to wheelchair-seat height. HHS and DOJ enforce 17–19″ today; the 2024 standard says 17″. Tables that reach 17″: UMF FusionFREEDOM and LibertyPRO, Midmark 228, 229 and 626.

21×17″

Transfer surface

A seat at least 21″ wide and 17″ deep that patients can reach from two sides. Every UMF and Midmark table here has a 28″-wide top.

6″

Patient-lift clearance

At least 6″ of room under the base for a portable floor lift. Midmark lists the 228, 229 and 626 as compatible; ask us about other models.

25″

Range of positions

A high transfer position at 25″, with at least four stops between low and high. Power lifts cover this.

Who has to comply, and by when

Who New equipment you buy or lease must be accessible At least one accessible exam table and scale
Providers that receive HHS fundingSection 504 · 45 CFR 84.92 Since Jul 8, 2024 Since Jul 8, 2026 Now required
State and local government facilitiesADA Title II · DOJ rule, Aug 2024 Since Oct 8, 2024 Since Aug 9, 2026 Now required
  • You don't have to replace every table. New purchases must be accessible until 10% of each equipment type is (20% at rehab and physical therapy facilities).
  • Most practices are covered. HHS estimates about 92% of doctors' offices and all hospitals receive its funding, including Medicare and Medicaid.

What happens if you're not compliant

  1. A patient complains

    To HHS's Office for Civil Rights, or to DOJ for government facilities.

  2. A corrective plan

    Buy accessible equipment, train staff and report back, often for one to two years.

  3. Funding at risk

    If a provider won't fix it, HHS can suspend or end its federal funding.

  4. Lawsuits

    Patients can also sue directly.

Not sure where you stand? Book a free 15-minute ADA review.

Common questions

Does a table that lowers to 18″ or 19″ still count?

Yes, under current HHS and DOJ enforcement, which accepts a low height of 17–19″. The 2024 Access Board update lowered the standard to 17″. Neither agency has adopted that change yet, though DOJ has said it will consider doing so in a future rule. For a new purchase, a 17″ table covers you either way. Midmark itself suggests replacing a 224 or 225 with a 228 or 229 to prepare for that change.

Is the table compliant straight out of the box?

Usually not entirely. On most chairs the transfer rails, and leg supports if you use stirrups, are separate accessories. UMF and Midmark both say to order their compliant rails with the chair. We'll include them on your quote.

Do I need an accessible scale too?

If you weigh patients, yes. Both rules require at least one accessible weight scale in addition to the exam table. See our ADA wheelchair scales.

Can the Midmark 626's built-in scale be my accessible scale?

It weighs patients who can transfer onto the chair. Patients who can't transfer still need to be weighed, so most practices add a roll-on wheelchair scale. Check with your compliance advisor before counting a chair scale as your accessible scale.

Is there a tax credit?

Yes, for small practices. Businesses with 30 or fewer employees or $1 million or less in revenue can claim the federal Disabled Access Credit: half of eligible spending over $250, up to $5,000 a year. Buying accessible equipment counts. Read our tax credit overview and confirm with your tax advisor.

Want a second opinion?

Authorized UMF Medical and Midmark dealer for 25 years. We'll confirm the model, add the compliant rails and quote delivery.

800-287-2250
Monday to Friday, 9 to 5 Eastern · sales@examtablesdirect.com
Book a free ADA review

Specs last verified October 2026. This guide summarizes manufacturer specifications and federal rules to help with purchasing decisions. It isn't legal advice. Features vary by model number and configuration, and manufacturers change specifications without notice. Confirm your requirements with your compliance officer and the official standards.